Category: Barrier Terminal Block
Item | Data | ||
APPROVAL | / | ||
Test standard | UL1059 | ||
Pitch [mm] | 9.52 | ||
Poles | 4-20P | ||
UL1059Test data | UL File Number E228872 | ||
Use group | B | C | D |
Rated voltage [V] | 300 | / | / |
Rated current [A] | 20 | / | / |
Rated connection capacity (solid/stranded) [AWG] | 18-Dec | ||
Rated torque [Lb. in] | 12.4 | ||
General data | / | ||
Screw | M3.5 | ||
Inflammability class UL94 | V-0 | ||
Ambient temperature [℃] | -30~+120 | ||
Relative humidity | 5%-95% | ||
Inspection standard | MIL-STD-105E II | ||
AQL | 0.65 | ||
Warranty | 12 months | ||
Material and plating | / | ||
Housing | PA66 | ||
Contact | Steel,Zn plated | ||
Contact | Copper alloy,Sn plated | ||
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
Tightening process should be steady, can’t use explosive force. |
Please Leave Your Product Enquiry Here. We will Get Back To You Soon.